Meaning
A joint is where two sheet parts meet and are held, by a weld, a lap, a hem or a tab in a slot. Its quality depends on the gap, the thickness of each part and the method that closes it. In ISO 5817 the joint, not the whole product, is the unit that receives a quality level. One part can therefore carry different levels on different joints.Level per Joint
ISO 5817 lets a drawing give one level for the whole part and another for the joints that need it. An enclosure seam that is ground flush and painted may take level C. A pressure-bearing or fatigue-loaded joint may call for level B, with the rest at D. The standard asks for the choice before production starts.Read More
Gap and Fit-Up
Most distortion is settled before the first seam, by the way the joint is assembled. TWI says tack welds set and hold the joint gap and resist transverse shrinkage. With too few tacks, the joint closes up as welding proceeds. On thick plate cut by laser, ISO 9013 sets the cut size as the assembly size reduced by the limit deviation. The gap is then a number the designer chose.Thickness Stack
A joint that stacks layers adds their thickness bands. Three layers of 2 mm (0.079 in) cold rolled sheet on normal tolerance can carry 0.30 mm (0.012 in) of excess or shortfall. On galvanized sheet, the zinc adds to the stack, so the drawing says whether the nominal is bare or coated. A tab joint cut to the bare value meets a coated sheet up to the coating thickness thicker.Joint Strength
A welded aluminum joint has no catalog strength in the 5052 datasheets. A drawing that relies on the full H32 yield across such a joint asks a question the sheets do not answer. The load the joint carries therefore goes on the drawing, so a strength test is planned. ISO 5817 itself does not cover fitness for purpose, apart from its fatigue annex.