Meaning
Linear misalignment between plates is how far two welded sheets sit out of line at a joint, limited at every ISO 5817 level. Plates cannot be held in exact register, so even level B keeps an allowance. On thin sheet the allowance is a fraction of the thickness plus a fixed term. That fixed term makes the thinner plate the one that suffers.Thin Sheet Limits
For material 0.5 to 3 mm (0.02 to 0.12 in), the limits use t, the thinner plate. Level B allows 0.1 t + 0.2 mm (0.008 in). Level C allows 0.15 t + 0.2 mm (0.008 in), and level D 0.25 t + 0.2 mm (0.008 in). On 2 mm (0.079 in) sheet, the three come to 0.4, 0.5 and 0.7 mm (0.016, 0.020 and 0.028 in).Read More
Worked Values
On 1.5 mm (0.059 in) 316L, the limits are 0.35, 0.43 and 0.58 mm (0.014, 0.017 and 0.023 in). On 0.8 mm (0.031 in) sheet, level B allows 0.28 mm (0.011 in). That is about a third of the sheet thickness. The whole spread between the best and loosest level on 2 mm (0.079 in) sheet is 0.3 mm (0.012 in).Holding Register
Misalignment is set at fit-up. Tacks hold the joint gap and resist transverse shrinkage, per TWI. A tab-and-slot part locates its neighbors like a row of built-in tacks. Its fit, in turn, depends on the laser cut and the bend before it.On the Drawing
A drawing names the level per joint and the edition, ISO 5817:2023. The misalignment limit then follows from the thinner plate’s thickness.