Meaning
The K-factor is the position of the neutral line within the sheet thickness, as a fraction of it, used to calculate the bend allowance and so the length of a flat pattern. Durma’s bend allowance formula multiplies the bend angle, in radians, by the inside radius plus K times the thickness. No single value covers every material, thickness, radius and bending method.Typical Values
Durma’s reference table starts air bending at 0.33 for soft material with a radius under one thickness, 0.40 to 0.45 between one and three thicknesses, and 0.50 above three, with bottoming higher in the same table. Its worked example uses 0.43 for medium steel at a radius of 1.2 times the thickness. On a 90 degree bend in 2 mm mild steel with a 2.6 mm (0.10 in) radius, moving K from 0.43 to 0.40 shortens the flat blank by about 0.1 mm (0.004 in).Read More
In the Flat Pattern
Durmapress warns that a flat pattern built on a K-factor or radius the actual tools do not produce moves every formed size, however well the machine runs. Autodesk notes that for a part with only 90 degree bends of one radius, a bend table gains nothing over an adjusted K-factor.In Springback
The Fabricator’s springback calculation takes the K-factor alongside the modulus of elasticity, the yield strength, the inside radius, the thickness and the included angle.Getting It Right
A reliable value comes from a test bend in the production die: the flanges are measured, the bend deduction is calculated back from a known blank length, and the value is stored with the material lot, die and punch. A change of die width calls for a fresh measurement, since the opening and the radius move together.